22 KW PUMP

Pump driven by Freecon PV500-4T-030B-H VSD

Dc power supplied by Canadian 555w pv modules

Voc/panel = 48.8v     Isc/panel = 14.05A

VSD input uses 6 strings each with 14 PV modules connected in series

The 6 strings parallel at the vsd

String voltages:

String 1: 648V

String 2: 648V

String 3: 648V

String 4: 647V

String 5: 646V

String 6: 648V